AdvantaBio® EcoFlex™ APEF-BP Biopharmaceutical Grade TPE Tubing

AdvantaBio logo

EcoFlex™ is AdvantaPure’s newest translucent thermoplastic elastomer (TPE) single-use tubing, engineered to support sustainable biopharmaceutical and pharmaceutical manufacturing applications. Based on the proven formulation of AdvantaPure’s flagship AdvantaFlex® APAF TPE tubing, EcoFlex delivers the same trusted performance, flexibility, and durability required for critical single-use processes. By replacing a traditional fossil-based oil with a bio-based oil in the polymer formulation, EcoFlex enhances product sustainability while maintaining the consistent performance, quality, and reliability demanded in regulated environments.

A sealable and weldable product, EcofFlex is suited to a wide range of applications. For current AdvantaFlex APAF users, EcoFlex provides a more sustainable product providing a reduction of product carbon footprint by approximately 15% with no changes to form, fit, function, manufacturing process, specifications, or regulatory testing compliance.

Key Features & Benefits

 
  • High-quality aseptic sealing disconnection
  • High strength, quality aseptic welded connections
  • Low absorption and good chemical resistance
  • Translucent for fluid flow visibility
  • Free of silicone oils
  • Wide range of standard sizes from 0.125” (3.175 mm) through 1” (25.4 mm) I.D.
  • Available as leak-proof overmolded connections
  • Custom lengths, sizes, and packaging available
  • Security of supply with redundant manufacturing
  • Manufactured with a focus on sustainability
  • Comprehensive validation package to expedite qualification and validation
 

Product Specifications

Part NumberI.D.WallO.D.Working Pressure 3:1 Safety Factor 70°F (21.1°C)Bend Radius
 inmminmminmmPSIBarinmm
A75300200.1253.180.0631.600.2506.35302.10.2506.35
A75300460.1884.780.0942.380.3759.52322.20.3759.53
A75300590.2506.350.0631.590.3759.52201.40.68817.47
A75300720.2506.350.0942.380.43811.11231.60.58314.81
A75300850.2506.350.1253.180.50012.70302.10.52113.23
A75301370.3759.520.1253.180.62515.88241.60.91723.29
A75301630.50012.700.1253.180.75019.09221.51.41735.99
A75301890.75019.050.1253.181.00025.40171.23.25082.55

NOTE: Not all standard part numbers are stocked items. For the up-to-date list of stocked sizes and lengths available, please contact your sales representative.

Non-listed sizes and custom lengths are available by special order. Coils are supplied double bagged in heat-sealed polybags and bulk packed. Contact your AdvantaPure sales representative for other packaging options.

NOTE: The data listed throughout this datasheet is meant only as a guide to aid in the design and is believed to be reliable; however, nothing stated shall constitute a guarantee or warranty for any application. Product field testing should be performed to find the actual values for a specific application.

ASTM Method Value
Durometer, Shore A D2240 65
Specific Gravity D792 0.89
Ultimate Tensile, psi (MPa) D412 1000 (6.89)
Ultimate Elongation, % D412 550
Tensile Modulus 100%, psi (MPa) D412 410 (2.83)
Tensile Modulus 300%, psi (MPa) D412 640 (4.41)
Tear Strength, Die B, ppi (kN/M) D624 240 (42.0)
Compression Set, % D395B 25
  • USP <665> Extractables/Leachables
  • USP <87> Cytotoxicity MEM Elution
  • USP <88> Class VI
  • USP <85> Bacterial Endotoxin
  • European Pharmacopeia 3.2.9
  • ISO 10993-5 (Cytotoxicity, In Vitro)
  • RoHS Compliant
  • REACH Compliant
  • ADCF Compliant

Acids, Dilute / Weak Acceptable
Acids, Strong / Concentrated Acceptable
Bases, Dilute / Weak Acceptable
Bases, Strong / Concentrated Acceptable
Salts Acceptable
High Purity Water Acceptable
Oil/Water Emulsion Test Before Use
Alcohol Not Recommended*
Organic Solvent Not Recommended
*Brief or intermittent contact is acceptable

Available with validated sterility assurance of 10-6 via
gamma irradiation per ISO 11137 method VDmax 25. A full
sterility validation guide is available upon request.

Autoclave One-time cycle at 121°C, 30 min
Gamma Irradiation One-time up to 40 kGy
X-Ray One-time up to 40 kGy

Typical Applications

Icon of illustration of a Sealed tube

Aseptic welding connections

Icon of illustration of a Sealed tube

Aseptic sealing disconnection

Image of tubing set with two aseptic connectors on the end and a molded Y connection

Single-use fluid transfer sets

Illustrated Icon of Buffer and regent storage containers

Biopharmaceutical production, sampling and delivery systems

Icon of a petri dish with cells

Cell media, harvesting, and fermentation

Final fill icon

Buffer and media preparation

bag-assembly

Ideal for use in assembles and bag manifolds

Icon of filters

Filtration

Suggested Additional Components

Molded Tubing
Ends

Ideal for aseptic transfer and processing, overmolded with multi-port sanitary clamp and ends to form a smooth fluid path.

Overmolding - Connections and Assemblies

AdvantaSil APSPG-MAX sizes can be integrated into our assemblies and manifolds. Choose from standard available wyes, tees, sanitary ends, crosses, and reducers, or opt for our custom overmolding design services to create custom pieces for your unique application.

Tubing Kits

Built-to-order in an ISO Class 7 cleanroom, assembled with various components for convenience and efficiency.

Sterile Bottle Assemblies

Provide a ready-to-use, cost-effective solution for aseptic
sampling, cell growth, and filling applications. The robust molded BioClosure® is designed for storage and containment.